RE-ON MIG OA 67

Ceweld product
Type
Tubular wire weldable without protective gas for rebuilding and buffer layers before hardfacing with extreme resistance to heavy impact loads.
classification
EN ISO
14700: T Fe9
DIN
8555: MF 7-GF-250-KNP
Applications
Rebuilding heavy steel parts, buffer layers, rails, rails crossings, dredger teeth, blast furnace mantles etc..
Type
Tubular wire weldable without protective gas for rebuilding and buffer layers before hardfacing with extreme resistance to heavy impact loads.
Applications
Rebuilding heavy steel parts, buffer layers, rails, rails crossings, dredger teeth, blast furnace mantles etc..
Propriétés

Austenitic deposit with strain hardening properties and no limmits in the number of layers. The deposit is non magnetic and can not be flame cut. 

Classification
EN ISO
14700: T Fe9
DIN
8555: MF 7-GF-250-KNP
Convient pour

Rebuilding, buffer layers, rails, rails crossings, dredger teeth, blast furnace mantles

Positions de soudage
PA
PB
PC
Etuvage
140°C / 24 hr
Note title
Hardness HB
after hardening: 500HB
Analyse
C Si Mn Cr Ni Mo Nb Ti V N Fe W B Co Cu Al
0.45 0.4 15.7 14.8 1.25 0.55 0.25 Rem.
Propriétés mécaniques
Heat
Treatment
RP0,2
(MPa)
Rm
(MPa)
A5
(%)
Hardness
As Welded 240 HB